NSN: 5925-01-361-1523

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Bushing Length

    0.260 inches nominal

  • Body Length

    1.120 inches minimum and 1.160 inches maximum

  • Body Width

    0.538 inches minimum and 0.562 inches maximum

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.230 inches minimum and 2.270 inches maximum

  • Special Handling Feature

    fragile

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    80.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Nominal Thread Size

    0.472 inches

  • Thread Series Designator

    unef

  • Body Style

    1a single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    0.800 inches nominal

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    8.0 amperes ac single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct and 65.000 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    corrosion resistant and humidity resistant and fungus resistant

  • Frequency In Hertz

    50.0 or 60.0

  • Terminal Type And Quantity

    2 tab w/screw

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...