NSN: 5925-01-372-0863

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Reset Method

    manual

  • Maximum Continuous Load Current Rating Per Pole

    8.0 amperes ac second location

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Trip Release Characteristic

    time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes dc first location

  • Nominal Thread Size

    0.375 inches

  • Trip Release Method

    magnetic all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct second location and 0.060 minimum at 200 pct first location and 1.700 maximum at 200 pct second location

  • Frequency In Hertz

    60.0 second location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Terminal Type And Quantity

    4 wire hook

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc first location

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac second location

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc first location

  • Manual Actuator Type And Quantity

    1 toggle

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac second location

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Length

    1.562 inches maximum

  • Thread Series Designator

    unef

  • Body Width

    1.281 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.600 maximum at 200 pct first location

  • Bushing Length

    0.380 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...