NSN: 5925-01-377-3478
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location and 65.0 dc single location
-
Actuator Function
reset
-
Thread Series Designator
unc
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac single location and 30.0 amperes dc single location
-
Body Width
0.750 inches nominal
-
Mounting Facility Type And Quantity
2 threaded hole
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 single location
-
Pole Quantity
1
-
Thread Tolerance Class
external
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.138 inches
-
Main Contact Tripping Mechanism Type
trip free
-
Body Length
2.500 inches nominal
-
Boss Height
0.140 inches nominal
-
Body Style
single pole type
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location and 5000.0 dc single location
-
Trip Release Method
magnetic-hydraulic single location
-
Frequency In Hertz
60.0 single location
-
Trip Release Characteristic
instantaneous single location
-
Mounting Surface To Terminal End Distance
2.481 inches nominal
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
1.938 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
-
Terminal Type And Quantity
2 threaded stud
-
End Item Identification
panel, 24vdc, p/n 2009-002-03 onboard 47 ft mlb coast guard vessels