NSN: 5925-01-379-7451

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac all locations and 2.0 amperes dc all locations

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac all locations and 2000.0 dc all locations

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations and 28.0 dc all locations

  • Body Length

    2.000 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 all locations

  • Unpackaged Unit Weight

    2.600 ounces

  • Internal Trip Release Configuration

    series trip all locations

  • Body Height

    1.770 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.595 inches minimum and 0.655 inches maximum

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-single actuator type

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Width

    1.540 inches nominal

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Terminal Type And Quantity

    4 tab, solder lug

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant and humidity resistant

  • Boss Height

    0.220 inches minimum and 0.280 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct all locations and 9.000 maximum at 200 pct all locations

  • Case Material

    plastic

  • Mounting Facility Type And Quantity

    2 clip

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...