NSN: 5925-01-386-1283

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    11b multipole-single actuator type

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    5.250 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.880 inches nominal

  • End Item Identification

    an/fps117v3

  • Boss Height

    0.125 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Auxiliary Trip Coil Voltage Type And Rating In Volts

    120.0 ac nominal all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole two

  • Trip Release Duty Cycle

    intermittent all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    25.000 minimum at 200 pct all locations and 150.000 maximum at 200 pct

  • Switch Current Rating And Type In Amps

    6.0 ac and 0.5 dc and 0.2 dc

  • Body Length

    6.312 inches nominal

  • Body Width

    4.125 inches nominal

  • Body Height

    3.188 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.188 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac all locations

  • Trip Release Characteristic

    instantaneous all locations and time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Auxiliary Switch Function And Quantity

    1 control

  • Switch Location And Position Designation

    internal at pole one

  • Trip Release Ambient Temp Rating

    -40.0 deg celsius minimum all locations and 70.0 deg celsius maximum

  • Switch Voltage Rating And Type In Volts

    240.0 ac and 125.0 dc and 250.0 dc

  • Special Features

    factory installed wiring on sw

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 compression

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...