NSN: 5925-01-387-6473
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Release Characteristic
instantaneous all locations
-
Trip Release Method
magnetic all locations
-
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac all locations
-
Overall Height
2.375 inches nominal
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Actuator Function
trip-reset
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
-
Reset Method
manual
-
Mounting Facility Type And Quantity
6 clip
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Terminal Type And Quantity
3 compression and 3 tab, solder lug
-
Case Material
plastic
-
Main Contact Tripping Mechanism Type
trip free
-
Frequency In Hertz
60.0 all locations
-
Manual Actuator Type And Quantity
3 toggle
-
Body Style
rectangular dimensional envelope
-
Overall Width
3.000 inches nominal
-
Overall Length
3.562 inches nominal
-
Pole Quantity
3
-
Internal Trip Release Configuration
series trip all locations
-
Circuit Protection Type
overcurrent all locations
-
Actuator Position Designation
at each pole
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac all locations