NSN: 5925-01-394-8251

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Switch Contact Arrangement

    single pole, double throw

  • Switch Current Rating And Type In Amps

    10.0 ac and 3.0 dc

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct all locations and 150.000 maximum at 200 pct all locations

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Body Width

    2.265 inches maximum

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac all locations

  • Bushing Length

    0.625 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Nominal Thread Size

    0.300 inches

  • Terminal Type And Quantity

    6 screw

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Thread Series Designator

    un

  • Switch Terminal Type

    screw

  • Center To Center Distance Between Terminals Parallel To Length

    2.094 inches nominal

  • Actuator Position Designation

    at pole two

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    magnetic all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Thread Quantity Per Inch

    32

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Body Length

    2.265 inches maximum

  • Switch Location And Position Designation

    internal at pole three

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Mounting Surface To Terminal End Distance

    2.790 inches maximum

  • Reset Method

    manual

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...