NSN: 5925-01-425-4332

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac second location and 10.0 amperes dc second location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac second location and 1000.0 dc second location

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 first location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac first location

  • Trip Release Characteristic

    time delay second location

  • Center To Center Distance Between Terminals Parallel To Length

    1.560 inches nominal

  • Frequency In Hertz

    60.0 second location or 50.0 second location or 400.0 second location

  • Mounting Facility Type And Quantity

    4 clip

  • Trip Release Characteristic

    time delay first location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac first location and 1000.0 dc first location

  • Frequency In Hertz

    60.0 first location or 50.0 first location or 400.0 first location

  • Internal Trip Release Configuration

    series trip first location

  • Auxiliary Trip Coil Voltage Type And Rating In Volts

    115.0 ac nominal second location

  • Body Style

    multipole-multiple actuator type

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac second location

  • Circuit Protection Type

    overcurrent second location

  • Body Length

    2.000 inches nominal

  • Actuator Function

    trip-reset

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.400 minimum at 150 pct second location and 6.000 maximum at 150 pct second location

  • Circuit Protection Type

    overcurrent first location

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac first location and 10.0 amperes dc first location

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Pole Quantity

    2

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Actuator Position Designation

    at each pole

  • Internal Trip Release Configuration

    series trip w/remote trip feature second location

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 second location

  • Terminal Type And Quantity

    5 knife blade

  • Manual Actuator Type And Quantity

    2 toggle

  • Trip Release Method

    magnetic first location

  • Trip Release Duty Cycle

    continuous second location

  • Body Width

    1.500 inches nominal

  • Mounting Surface To Terminal End Distance

    1.950 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    6.000 minimum at 150 pct first location and 70.000 maximum at 150 pct first location

  • Trip Release Method

    magnetic second location

  • Case Material

    plastic

  • Boss Height

    0.130 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...