NSN: 5925-01-429-3850

Technical Characteristics

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    8.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.063 inches nominal

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 push button

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Mounting Surface To Terminal End Distance

    1.625 inches maximum

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.406 inches nominal

  • Pole Quantity

    1

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    575.0 dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Overall Length

    3.227 inches nominal

  • Inclosure Protection Type For Which Designed

    vibration resistant and shock resistant and salt spray proof and fungus resistant

  • Maximum Continuous Load Current Rating Per Pole

    90.0 amperes dc single location

  • Body Style

    single pole type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Case Material

    plastic

  • Terminal Type And Quantity

    2 threaded stud

  • Fragility Factor

    moderately rugged

  • Body Width

    1.875 inches nominal

  • Nominal Thread Size

    0.190 inches

  • Reset Method

    manual

  • Thread Series Designator

    unf

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...