NSN: 5925-01-452-9846

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Circuit Protection Type

    overvoltage all locations

  • Reset Method

    manual

  • Trip Delay Time In Seconds Per Rated Continuous Current

    125.000 maximum at 200 pct all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Thread Series Designator

    unc

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    60.0 all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Center To Center Distance Between Terminals Parallel To Length

    13.124 inches nominal

  • Nominal Thread Size

    0.138 inches

  • Body Width

    8.250 inches nominal

  • Pole Quantity

    3

  • Trip Release Method

    thermal-magnetic all locations

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.312 inches nominal

  • Trip Release Characteristic

    time delay all locations

  • Terminal Type And Quantity

    6 tab, solder lug

  • Manual Actuator Type And Quantity

    1 toggle

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Actuator Position Designation

    at pole two

  • Actuator Function

    trip-reset

  • Case Material

    metal

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Body Length

    16.125 inches nominal

  • Body Style

    multipole-single actuator type

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Inclosure Protection Type For Which Designed

    general purpose

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

  • Body Height

    4.500 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    150.0 amperes dc all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...