NSN: 5925-01-465-2672

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    2 threaded stud

  • Case Material

    plastic

  • Switch Location And Position Designation

    internal at pole one

  • Body Width

    3.103 inches nominal

  • Manual Actuator Type And Quantity

    3 toggle

  • Mounting Facility Type And Quantity

    3 slot and 3 threaded hole

  • Mounting Slot Width

    0.164 inches nominal

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Switch Current Rating And Type In Amps

    10.0 ac and 5.0 dc

  • Main Contact Tripping Mechanism Type

    trip free

  • Nominal Thread Size

    0.138 inches

  • Body Height

    2.827 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Switch Contact Arrangement

    single pole, double throw

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Body Style

    multipole-multiple actuator type

  • Center To Center Distance Between Terminals Parallel To Length

    4.750 inches nominal

  • Trip Release Method

    magnetic-hydraulic all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Thread Quantity Per Inch

    32

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.026 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    5.032 inches nominal

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.026 inches nominal

  • Reset Method

    manual

  • Actuator Position Designation

    at each pole

  • Thread Series Designator

    unc

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Switch Terminal Type

    tab, solder lug

  • Body Length

    5.844 inches nominal

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...