NSN: 5925-01-497-2042

Technical Characteristics

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac all locations

  • Nominal Thread Size

    0.138 inches

  • Frequency In Hertz

    60.0 all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    1000.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct all locations and 0.250 maximum at 400 pct all locations and 1.000 maximum at 200 pct all locations and 0.032 minimum at 400 pct all locations and 0.110 maximum at 800 pct all locations

  • Manual Actuator Type And Quantity

    2 toggle

  • Ultimate Trip Time Per Pole In Seconds

    0.800 minimum all locations and 7.000 maximum all locations

  • Switch Terminal Type

    pin

  • Mounting Surface To Terminal End Distance

    3.460 inches minimum and 3.580 inches maximum

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Boss Height

    0.220 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    50.0 ac all locations

  • Terminal Type And Quantity

    4 threaded stud

  • Test Data Document

    81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.026 inches nominal

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • End Item Identification

    weapon launch console assembly for losangeles class submarine 688

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Inclosure Protection Type For Which Designed

    moisture resistant and fungus resistant and salt water resistant

  • Body Width

    2.072 inches maximum

  • Circuit Protection Type

    overcurrent all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.996 inches minimum and 1.056 inches maximum

  • Pole Quantity

    2

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Special Features

    mount circuit breaker in vertical position

  • Body Length

    5.125 inches nominal

  • Specification/Standard Data

    81349-mil-c-55629/15 government specification

  • Center To Center Distance Between Terminals Parallel To Length

    3.480 inches minimum and 3.614 inches maximum

  • Switch Location And Position Designation

    internal at pole one

  • Switch Contact Arrangement

    double pole, single throw, normally open

  • Case Material

    plastic

  • ~1

    data on certain environmental and performanc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.