NSN: 5925-01-501-7437
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc fourth location
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Circuit Protection Type
overcurrent all locations
-
Thread Series Designator
unc
-
Reset Method
manual
-
Trip Release Characteristic
time delay all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
63.000 nominal at 125 pct first location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac second location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
-
Trip Delay Time In Seconds Per Rated Continuous Current
63.000 nominal at 125 pct second location
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.000 nominal at 125 pct fourth location
-
Boss Height
1.042 inches nominal
-
Body Style
multipole-multiple actuator type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Trip Release Method
thermal-magnetic all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
63.000 nominal at 125 pct third location
-
Special Features
1st pole has single pole double throw auxiliary switch
-
Body Length
3.015 inches nominal
-
Case Material
metal
-
End Item Identification
5895-01-467-7213
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac third location
-
Nominal Thread Size
0.138 inches
-
Frequency In Hertz
60.0 all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Body Width
2.490 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac first location
-
Maximum Continuous Load Current Rating Per Pole
120.0 milliamperes dc fourth location
-
Mounting Surface To Terminal End Distance
2.529 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac second location
-
Trip Release Ambient Temp Rating
70.0 deg celsius nominal all locations
-
Mounting Facility Type And Quantity
6 threaded stud
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac first location
-
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac third location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.250 inches nominal
-
Pole Quantity
4
-
Terminal Type And Quantity
6 threaded stud