NSN: 5925-01-511-5852
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
End Item Identification
virginia class submarine
-
Special Features
used on the unit data acq; based on mil-prf-39019/3
-
Pole Quantity
2
-
Bushing Length
0.332 inches minimum and 0.380 inches maximum
-
Reset Method
manual
-
Mounting Facility Type And Quantity
4 threaded bushing
-
Trip Release Characteristic
time delay all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
-
Internal Trip Release Configuration
series trip all locations
-
Terminal Type And Quantity
4 screw
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 all locations
-
Operating Voltage Type And Rating Per Pole In Volts
26.0 dc all locations
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 nominal at 135 pct all locations and 60.000 maximum at 135 pct all locations
-
Case Material
metal
-
Part Name Assigned By Controlling Agency
magnetic circuit breaker
-
Nominal Thread Size
0.138 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
0.720 inches minimum and 0.780 inches maximum
-
Body Length
1.562 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc all locations
-
Center To Center Distance Between Terminals Parallel To Length
0.906 inches maximum
-
Frequency In Hertz
400.0 all locations
-
Thread Series Designator
unef
-
Body Width
1.281 inches maximum
-
Mounting Surface To Terminal End Distance
1.950 inches maximum
-
Circuit Protection Type
undercurrent all locations