NSN: 5925-01-512-8731

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81349-mil-prf-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general

  • ~1

    type data on certain environmental and performa

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • End Item Identification

    aft steering unit

  • Trip Release Characteristic

    time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Nonturn Device Location

    at 12 oclock

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations and 500.0 dc all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 all locations

  • Terminal Type And Quantity

    4 tab w/screw

  • Nominal Thread Size

    0.375 inches

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc all locations and 240.0 ac all locations

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    60.0 all locations or 400.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac all locations and 10.0 amperes dc all locations

  • Specification/Standard Data

    81349-mil-prf-39019/3 government specification

  • Body Length

    1.562 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Thread Series Designator

    unef

  • Special Features

    2 mounting screws to enhance vibration resistance; circuit breaker furnished with nonturn devise

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct all locations and 9.000 maximum at 200 pct all locations

  • Body Width

    1.281 inches maximum

  • Ultimate Trip Time Per Pole In Seconds

    3.000 minimum all locations and 60.000 maximum all locations

  • Features Provided

    high inrush protection

  • Mounting Surface To Terminal End Distance

    1.950 inches maximum

  • Nonturn Device Radius

    0.325 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...