NSN: 5925-01-519-1884
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
End Item Identification
t6a training aircraft
-
Reset Method
electric
-
Trip Release Characteristic
instantaneous all locations
-
Terminal Type And Quantity
1 solder stud
-
Arc Quenching Method
air
-
Circuit Protection Type
overvoltage all locations
-
Pole Quantity
1
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3000.0 dc all locations
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes dc single location
-
Body Style
single pole type
-
Mounting Facility Type And Quantity
1 threaded stud
-
Trip Release Method
solid state all locations
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 dc single location
-
Case Material