Technical Characteristics

  • ~1

    single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2800.0 ac single location and 4800.0 dc single location

  • Trip Release Method

    magnetic single location

  • Reset Method

    manual

  • End Item Identification

    boeing b757 aircraft

  • Actuator Position Designation

    at pole one

  • Mounting Surface To Terminal End Distance

    1.860 inches maximum

  • Actuator Function

    trip-reset

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Unpackaged Unit Weight

    0.150 pounds

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct single location and 1.000 minimum at 600 pct single location and 7.000 maximum at 400 pct single location and 2.000 minimum at 400 pct single location and 55.000 maximum at 200 pct single location and 3.500 maximum at 600 pct

  • Case Material

    plastic

  • Thread Series Designator

    uns

  • Nominal Thread Size

    0.4688 inches

  • Body Width

    0.750 inches maximum

  • Bushing Length

    0.250 inches maximum

  • Terminal Type And Quantity

    2 tab w/screw

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Body Length

    1.152 inches maximum

  • Body Style

    single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    0.704 inches nominal

  • Frequency In Hertz

    400.0 single location

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location and 15.0 amperes dc single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay single location

  • Special Features

    thread class 2a; barrier extends from bottom of breaker 0.500 inch, length is 1.218 inches nominal, and thickness is 0.031 inch nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    200.0 ac single location and 28.0 dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Pole Quantity

    1

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...