NSN: 5925-01-519-6744

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Case Material

    plastic

  • Body Width

    1.500 inches nominal

  • Terminal Type And Quantity

    4 threaded stud

  • Frequency In Hertz

    400.0 all locations

  • Manual Actuator Type And Quantity

    2 toggle

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Boss Height

    0.140 inches nominal

  • Body Length

    2.500 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic-hydraulic all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct all locations and 120.000 maximum at 200 pct all locations

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Mounting Surface To Terminal End Distance

    2.287 inches nominal

  • Thread Series Designator

    unf

  • Reset Method

    manual

  • Nominal Thread Size

    0.190 inches

  • Actuator Position Designation

    at each pole

  • Pole Quantity

    2

  • Circuit Protection Type

    overcurrent all locations

  • Special Features

    operating temperature minus 40.0 deg c to plus 85.0 deg c

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...