NSN: 5925-01-523-1581
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Type And Quantity
2 threaded stud
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
120.0 single location
-
Case Material
plastic
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
30.0 dc single location
-
Operating Voltage Type And Rating Per Pole In Volts
24.0 dc single location
-
Trip Release Characteristic
instantaneous single location
-
Mounting Facility Type And Quantity
1 slot
-
Mounting Slot Width
38.24 millimeters nominal
-
Body Style
single pole type
-
Body Length
73.41 millimeters nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
58.64 millimeters nominal
-
Maximum Continuous Load Current Rating Per Pole
30.0 amperes dc single location
-
Main Contact Tripping Mechanism Type
trip free
-
End Item Identification
nsn 2320-01-447-6345; chassis, truck; w/s: family of medium and light tactical vehicles (fmtv)
-
Internal Trip Release Configuration
series trip single location
-
Pole Quantity
1
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Body Width
43.28 millimeters nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
28.62 millimeters nominal
-
Circuit Protection Type
overcurrent single location
-
Manual Actuator Type And Quantity
1 push button
-
Storage Type
general purpose warehouse
-
Boss Height
9.9 millimeters nominal
-
Center To Center Distance Between Terminals Parallel To Length
58.64 millimeters nominal
-
Reset Method
manual
-
Body Height
46.58 millimeters nominal
-
Trip Release Method
magnetic single location
-
Actuator Function
reset