NSN: 5925-01-530-7029
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Width
0.750 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
35.0 amperes dc single location
-
Body Length
2.000 inches nominal
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal and 1 threaded hole
-
Terminal Type And Quantity
2 screw
-
Circuit Protection Type
overcurrent single location
-
Pole Quantity
1
-
Reset Method
manual
-
Actuator Function
trip w/separate reset
-
Thread Series Designator
un and unc
-
Nominal Thread Size
0.500 inches and 0.138 inches
-
Trip Release Method
magnetic single location
-
Operating Voltage Type And Rating Per Pole In Volts
80.0 dc single location
-
~1
single location and 0.031 minimum at 400 pct sing
-
Mounting Surface To Terminal End Distance
2.256 inches maximum
-
Body Style
single pole type
-
Center To Center Distance Between Terminals Parallel To Length
1.530 inches nominal
-
Unpackaged Unit Weight
2.200 ounces
-
Main Contact Tripping Mechanism Type
trip free
-
Trip Release Characteristic
time delay single location
-
Thread Quantity Per Inch
32 and 32
-
Internal Trip Release Configuration
series trip single location
-
Manual Actuator Type And Quantity
1 toggle
-
Part Name Assigned By Controlling Agency
magnetic circuit breaker
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.004 minimum at 1000 pct single location and 0.011 minimum at 600 pct single location and 0.500 maximum at 400 pct single location and 0.100 minimum at 200 pct single location and 1.200 maximum at 200 pct single location and 6.500 maximum at 125 pct