NSN: 5925-01-549-1403

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.800 minimum at 125 pct all locations and 0.006 minimum at 1000 pct all locations and 100.000 maximum at 125 pct all locations and 0.280 maximum at 1000 pct all locations

  • Terminal Type And Quantity

    4 quick disconnect, male

  • Trip Release Ambient Temp Rating

    -40.0 deg celsius minimum all locations and 85.0 deg celsius maximum all locations

  • Body Width

    1.515 inches maximum

  • Inclosure Protection Type For Which Designed

    moisture resistant and salt spray proof

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 dc all locations

  • Trip Release Duty Cycle

    continuous all locations

  • End Item Identification

    receiver, drt-1201b

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Surface To Terminal End Distance

    2.075 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3000.0 dc all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic all locations

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes dc all locations

  • Bushing Length

    0.240 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 all locations

  • Unthreaded Mounting Hole Diameter

    0.156 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Body Length

    2.000 inches nominal

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Pole Quantity

    2

  • Circuit Protection Type

    overcurrent all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...