Technical Characteristics
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location
-
Special Features
operating temperature minus 40.0 to plus 85.0 degrees c.
-
Inclosure Protection Type For Which Designed
shock resistant and vibration resistant
-
Thread Series Designator
unc
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Body Width
0.750 inches nominal
-
Actuator Function
trip-reset
-
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
-
Mounting Facility Type And Quantity
2 threaded hole
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
End Item Identification
radar tps-77
-
Pole Quantity
1
-
Thread Tolerance Class
2b internal
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.138 inches
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac single location
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Body Length
2.500 inches nominal
-
Mounting Surface To Terminal End Distance
2.860 inches nominal
-
Boss Height
0.140 inches nominal
-
Frequency In Hertz
50.0 single location or 60.0 single location
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac single location
-
Body Style
single pole type
-
Trip Release Method
magnetic-hydraulic single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.160 minimum at 200 pct single location and 1.600 maximum at 200 pct single location
-
Case Material
plastic
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
-
Terminal Type And Quantity
2 threaded stud