NSN: 5925-01-566-7983

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • ~1

    data on certain environmental and performance

  • Test Data Document

    81541-852-503-55 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Body Length

    2.490 inches nominal

  • Case Material

    plastic

  • Terminal Type And Quantity

    4 threaded stud

  • Trip Release Method

    solid state all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 125 pct all locations and 120.000 maximum at 125 pct all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac all locations

  • Body Width

    1.515 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    2.060 inches nominal

  • Boss Height

    1.940 inches nominal

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • End Item Identification

    4920-01-465-7013

  • Body Style

    multipole-single actuator type

  • Circuit Protection Type

    overvoltage all locations

  • Main Contact Tripping Mechanism Type

    nontrip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    0.750 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.156 inches nominal

  • Trip Release Characteristic

    time delay all locations

  • Part Name Assigned By Controlling Agency

    circuit breaker

  • Reset Method

    manual

  • Mounting Surface To Terminal End Distance

    0.655 inches nominal

  • Pole Quantity

    2

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...