NSN: 5925-01-591-4548
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
2
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches nominal
-
Reset Method
manual
-
End Item Identification
misc parts list for lcu 1617
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Body Length
2.000 inches nominal
-
Internal Trip Release Configuration
series trip all locations
-
Special Features
terminals are bus type, 10-32 screws; 50/60 hz; medium delay; black actuator with legend "on-off" in white; ul recognized and csa accepted
-
Terminal Type And Quantity
4 screw
-
Mounting Facility Type And Quantity
4 threaded hole
-
Center To Center Distance Between Terminals Parallel To Length
1.558 inches nominal
-
Mounting Surface To Terminal End Distance
2.032 inches nominal
-
Trip Release Method
magnetic-hydraulic all locations
-
Maximum Continuous Load Current Rating Per Pole
25.0 amperes dc all locations
-
Body Style
multipole-multiple actuator type
-
Actuator Position Designation
at pole two
-
Manual Actuator Type And Quantity
1 toggle
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
7500.0 dc all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Operating Voltage Type And Rating Per Pole In Volts
80.0 dc all locations
-
Body Width
1.515 inches nominal
-
Bushing Length
0.130 nominal inches
-
Case Material
plastic