NSN: 5925-01-591-6121

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • External Actuator Linkage Arrangement

    one and two linked

  • Mounting Facility Type And Quantity

    din rail

  • Operating Voltage Type And Rating Per Pole In Volts

    277.0 ac all locations and 480.0 ac all locations and 96.0 dc all locations

  • Internal Trip Release Configuration

    relay trip all locations

  • Boss Height

    16.0 millimeters nominal

  • Manual Actuator Type And Quantity

    2 toggle

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Part Name Assigned By Controlling Agency

    faz na miniature branch circuit breaker for highly inductive load

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations and 10000.0 dc all locations

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac all locations and 10.0 amperes dc all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    1000.0 all locations

  • End Item Identification

    aircraft c295

  • Center To Center Distance Between Terminals Parallel To Width

    17.7 millimeters nominal

  • Body Length

    105.0 millimeters nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 at 800 pct pascal all locations and 90.000 18 stage pascal all locations

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic all locations

  • Body Width

    35.4 millimeters nominal

  • Special Features

    suitable for applications where high levels of inrush current are expected; prevents nuisance tripping in high inductive apps

  • Actuator Position Designation

    at pole one and at pole two

  • Terminal Type And Quantity

    4 screw

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Actuator Function

    trip-reset

  • Reset Method

    manual

  • Body Height

    44.0 millimeters nominal

  • Pole Quantity

    2

  • Circuit Protection Type

    overcurrent all locations

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...