NSN: 5925-01-592-0051

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Reset Method

    manual

  • Nominal Thread Size

    0.500 inches

  • Thread Series Designator

    unf

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Body Length

    2.000 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Terminal Type And Quantity

    4 tab w/screw

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Actuator Position Designation

    at pole two

  • Mounting Surface To Terminal End Distance

    2.200 inches maximum

  • Manual Actuator Type And Quantity

    1 toggle

  • Maximum Continuous Load Current Rating Per Pole

    2.5 amperes dc all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    1000.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Bushing Length

    0.750 nominal inches

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Part Name Assigned By Controlling Agency

    upg series magnetic circuit breaker, panel seal, one bat handle per unit, two pole, screw terminals, series, 2.5 amp, dc 50/60hz, long delay

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • End Item Identification

    boat, barrier, 25ft, 25bb601 thru 25bb606

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations and 65.0 dc all locations

  • Body Width

    1.515 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.300 at 800 pct pascal all locations and 20.000 18 stage pascal all locations

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...