Technical Characteristics

  • Frequency In Hertz

    400.000 all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Mounting Facility Type And Quantity

    6 unthreaded hole

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    22.5 ac all locations

  • Reset Method

    manual

  • Special Features

    1 toggle handle per unit; sealed toggle w/bushing mounting; 3 pole; screw terminals w/barriers; series w/aux; 110 quick conn; 400 hz motor start delay; 150% trip; additional inertial delay

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Body Length

    2.000 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.156 inches nominal

  • Bushing Length

    0.240 inches nominal

  • Trip Release Method

    magnetic all locations

  • Actuator Position Designation

    at pole two

  • Trip Delay Time In Seconds Per Rated Continuous Current

    12.000 minimum at 200 pct all locations and 350.000 maximum at 200 pct all locations

  • Body Style

    multipole-single actuator type

  • Body Width

    2.265 inches maximum

  • Manual Actuator Type And Quantity

    1 toggle

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    1000.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Internal Trip Release Configuration

    series trip w/auxiliary load terminal all locations

  • Mounting Surface To Terminal End Distance

    1.687 inches nominal

  • Terminal Type And Quantity

    6 screw

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • End Item Identification

    b-1

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...