NSN: 5925-01-596-7554

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    2.490 inches maximum

  • Boss Height

    0.439 inches nominal

  • Part Name Assigned By Controlling Agency

    magnetic circuit breaker, bx style, one rocker handle per unit, accidental-off protection, 1 pole, series, 50/60 hz motor start

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    0.000 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac single location

  • Case Material

    plastic

  • Trip Release Method

    magnetic single location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Thread Series Designator

    unc

  • Mounting Surface To Terminal End Distance

    1.859 inches nominal

  • Reset Method

    manual

  • Body Width

    0.750 inches nominal

  • Actuator Function

    trip-reset

  • Terminal Type And Quantity

    2 screw

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Center To Center Distance Between Terminals Parallel To Length

    1.490 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct single location and 150.000 maximum at 200 pct single location

  • Circuit Protection Type

    overcurrent single location

  • Pole Quantity

    1

  • Special Features

    bx style has flat rocker actuator with accidental actuation protection

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    50.0 single location or 60.0 single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    1000.0 single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac single location

  • Body Style

    single pole type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...