NSN: 5930-00-053-8698
Switches
SWITCH,PRESSURE
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Pressure Switch Type
differential
-
Nonpile-Up Contact Arrangement
1 pole,single throw,normally open,momentary action
-
Contact Adjustability
deactuation point not adjustable and actuation point not adjustable
-
Pressure Connector Type
plain,threaded external
-
Media For Which Designed
gas
-
Hazardous Locations/Environmental Protection
watertight
-
Overall Length
2.120 inches minimum and 2.240 inches maximum
-
Overall Height
3.250 inches minimum and 3.440 inches maximum
-
Overall Width
3.000 inches minimum and 3.120 inches maximum
-
Mounting Method
inlet connection and outlet connection
-
Contact Action Stimulus
increase
-
Terminal Type
connector,plug
-
Contact Load Current Rating
5.0 amperes resistive load and 3.0 amperes inductive load and 3.0 amperes lamp load
-
Contact Stimulus Rating
5.00 actuation point nominal pounds per square inch and 3.00 deactuation point nominal pounds per square inch and 2.00 differential point nominal pounds per square inch
-
Contact Voltage Rating In Volts
24.0 dc at sea level
-
Pressure Connector Type
plain,threaded internal
-
Thread Series Designator
nptf