NSN: 5930-00-103-6379
Switches
SWITCH,PRESSURE
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Method
base and unthreaded hole
-
Overall Width
1.312 inches nominal
-
End Item Identification
nwaspclass lhd, countermeasure set, an/slq-32, ticonderoga class cg (47),radar (highpar) an/gpn-22(v), arleigh burke class ddg, nimitz class cvn, spruance class dd (963), forrestal class cv, oliver perry class ffg.
-
Media For Which Designed
liquid
-
Contact Voltage Rating In Volts
30.0 dc at sea level second voltage
-
Criticality Code Justification
feat
-
Pressure Connector Type
barbed, unthreaded external all connections
-
Outside Diameter
0.195 inches minimum all connections and 0.205 inches maximum all connections
-
Special Features
weapon system essential
-
Contact Stimulus Rating
0.50 actuation point nominal inches of water and 0.40 deactuation point nominal inches of water and 0.10 differential point nominal inches of water
-
Terminal Type
quick disconnect, male
-
Contact Load Current Rating
10.0 milliamperes resistive load second voltage
-
Sensing Element Burst Pressure
8.00 pounds per square inch gage
-
Longest Vertical Distance Between Mounting Centers
0.719 inches nominal
-
Style Designator
rectangular
-
Longest Horizontal Distance Between Mounting Centers
0.719 inches nominal
-
Inside Diameter
0.125 inches nominal all connections
-
Body Length
1.000 inches nominal
-
Contact Voltage Rating In Volts
115.0 ac at sea level first voltage
-
Nonpile-Up Contact Arrangement
1 pole, single throw, normally closed, momentary action
-
Overall Length
1.750 inches nominal
-
Contact Load Current Rating
10.0 milliamperes resistive load first voltage
-
Pressure Switch Type
gage
-
Contact Adjustability
deactuation point not adjustable and actuation point not adjustable
-
Overall Height
0.375 inches nominal
-
Operating Temp Rating
-40.0 deg fahrenheit minimum and 150.0 deg fahrenheit maximum
-
Unthreaded Mounting Hole Diameter
0.094 inches nominal
-
Mounting Facility Pattern
four position rectangular
-
Contact Action Stimulus
increase