NSN: 5930-00-144-2058
Switches
SWITCH,PRESSURE
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Method
bracket and unthreaded hole
-
Thread Series Designator
npt single pressure connection
-
Mounting Facility Pattern
isosceles triangle
-
Contact Load Current Rating
15.0 amperes resistive load first voltage
-
Contact Voltage Rating In Volts
250.0 ac at sea level first voltage
-
Inside Diameter
0.250 inches nominal single connection
-
Media For Which Designed
gas
-
Overall Height
5.750 inches nominal
-
Hazardous Locations/Environmental Protection
watertight
-
Overall Width
2.312 inches nominal
-
Contact Load Current Rating
15.0 amperes resistive load second voltage
-
Contact Adjustment Type
internal deactuation point hex nut and internal actuation point hex nut
-
Shortest Horizontal Distance Between Mounting Centers
1.625 inches nominal
-
Unthreaded Mounting Hole Diameter
0.203 inches nominal
-
Contact Adjustability
deactuation point adjustable, preset and actuation point adjustable, preset
-
Terminal Type
screw
-
Style Designator
rectangular
-
Thread Quantity Per Inch
18 single pressure connection
-
Contact Adjustment Range
+90.00/+3300.00 actuation point pounds per square inch and +60.00/+3270.00 deactuation point pounds per square inch
-
Contact Action Stimulus
increase
-
Contact Stimulus Rating
3000.00 actuation point nominal pounds per square inch and 30.00 differential point nominal pounds per square inch
-
Pressure Connector Type
plain, threaded internal single connection
-
Proof Pressure
12000.00 pounds per square inch
-
Nominal Thread Size
0.250 inches single pressure connection
-
Longest Vertical Distance Between Mounting Centers
3.312 inches nominal
-
Longest Horizontal Distance Between Mounting Centers
3.250 inches nominal
-
Pressure Switch Type
gage
-
Body Height
2.750 inches nominal
-
Contact Voltage Rating In Volts
125.0 ac at sea level second voltage
-
Overall Length
4.000 inches nominal
-
Nonpile-Up Contact Arrangement
1 pole, double throw, one position momentary