NSN: 5930-00-224-0378
Switches
SWITCH,THERMOSTATIC
SWITCH,THERMOSTATIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Contact Action Stimulus
increase
-
Bulb Diameter
0.375 inches nominal
-
Nonpile-Up Contact Arrangement
1 pole, single throw, both positions maintained
-
Mounting Method
bracket
-
Contact Adjustment Range
+60.00/+250.00 actuation point degrees fahrenheit
-
Longest Horizontal Distance Between Mounting Centers
1.750 inches nominal
-
Media For Which Designed
gas or liquid
-
Contact Voltage Rating In Volts
250.0 ac at sea level single voltage
-
Terminal Type
tab w/screw
-
Capillary Tube Length
84.000 inches nominal
-
Contact Load Current Rating
25.0 amperes resistive load single voltage
-
Temp Sensing Element Type
capillary tube-bulb
-
Contact Adjustability
actuation point adjustable