NSN: 5930-00-262-5870

Switches

SWITCH,THERMOSTATIC

5930 - Switches

SWITCH,THERMOSTATIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • ~1

    data on certain environmental and performance

  • ~1

    degrees fahrenheit

  • Contact Stimulus Rating

    125.00 deactuation point maximum degrees fahrenheit and 145.00 actuation point maximum degrees fahrenheit and 115.00 deactuation point minimum degrees fahrenheit and 135.00 actuation point minimum degrees fahrenheit and 20.00 differential point nominal

  • Contact Action Stimulus

    increase

  • Mounting Facility Pattern

    two position in-line

  • Contact Adjustability

    deactuation point not adjustable and actuation point not adjustable

  • Mounting Method

    bracket

  • Contact Load Current Rating

    5.0 amperes resistive load third voltage

  • Contact Voltage Rating In Volts

    115.0 ac at sea level second voltage

  • Overall Height

    0.632 inches maximum

  • Contact Load Current Rating

    1.0 amperes resistive load first voltage

  • Body Height

    0.384 inches maximum

  • Temp Sensing Element Type

    internal sensor

  • Contact Load Current Rating

    2.0 amperes resistive load second voltage

  • Terminal Type

    tab, solder lug

  • Distance Between Mounting Facility Centers

    0.937 inches nominal

  • Features Provided

    hermetically sealed case

  • Frequency In Hertz

    60.0 single voltage

  • Overall Length

    1.240 inches minimum and 1.260 inches maximum

  • Body Diameter

    0.640 inches maximum

  • Nonpile-Up Contact Arrangement

    1 pole, single throw, normally open, momentary action

  • Media For Which Designed

    gas

  • Style Designator

    disc w/flange

  • Contact Voltage Rating In Volts

    250.0 ac at sea level first voltage

  • Special Features

    gold plated contacts

  • Contact Voltage Rating In Volts

    30.0 dc at sea level third voltage

  • Test Data Document

    81349-mils24236 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...