NSN: 5930-00-270-4805
Switches
SWITCH,PRESSURE
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Special Features
phosphor bronze housing for oxygen service
-
Operating Temp Rating
-30.0 deg fahrenheit minimum and 580.0 deg fahrenheit maximum
-
Longest Horizontal Distance Between Mounting Centers
3.000 inches nominal
-
Body Height
10.312 inches nominal
-
Contact Voltage Rating In Volts
550.0 ac at sea level first voltage
-
Shortest Horizontal Distance Between Mounting Centers
1.500 inches nominal
-
Media For Which Designed
gas
-
Body Length
4.875 inches nominal
-
Mounting Facility Pattern
isosceles triangle
-
Contact Load Current Rating
4.0 amperes resistive load third voltage
-
Contact Adjustability
deactuation point adjustable and actuation point adjustable
-
Mounting Method
bracket and unthreaded hole
-
Precious Material And Location
contacts silver
-
Err Default
err default
-
Overall Width
3.000 inches nominal
-
Precious Material
silver
-
Contact Voltage Rating In Volts
115.0 dc at sea level fourth voltage
-
Unthreaded Mounting Hole Diameter
0.375 inches nominal
-
Contact Voltage Rating In Volts
115.0 ac at sea level second voltage
-
Contact Load Current Rating
4.0 amperes resistive load first voltage
-
Contact Adjustment Range
+250.00/+3000.00 actuation point pounds per square inch and +210.00/+2920.00 deactuation point pounds per square inch
-
Overall Length
5.750 inches nominal
-
Nominal Thread Size
0.438 inches single pressure connection
-
Features Provided
electrical access port
-
Pressure Switch Type
gage
-
Contact Voltage Rating In Volts
550.0 dc at sea level third voltage
-
Proof Pressure
3600.00 pounds per square inch gage
-
Thread Class
2b single pressure connection
-
Pressure Connector Type
plain, threaded internal single connection
-
Thread Quantity Per Inch
20 single pressure connection
-
Contact Action Stimulus
increase
-
Contact Adjustment Type
internal actuation point hex nut with scale and internal deactuation point hex nut with scale
-
Contact Load Current Rating
15.0 amperes resistive load second voltage
-
Thread Series Designator
unf single pressure connection
-
Overall Height
10.812 inches nominal
-
Terminal Type
screw
-
Style Designator
rectangular
-
Hazardous Locations/Environmental Protection
general purpose-nema type 1
-
Longest Vertical Distance Between Mounting Centers
4.250 inches nominal
-
Inside Diameter
0.438 inches nominal single connection
-
Contact Load Current Rating
15.0 amperes resistive load fourth voltage
-
Nonpile-Up Contact Arrangement
1 pole, double throw, one position momentary