NSN: 5930-00-431-5549

Switches

SWITCH,ROTARY

5930 - Switches

SWITCH,ROTARY

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Class

    2a single mounting facility

  • First Flat Length

    0.296 inches minimum single actuator and 0.328 inches maximum

  • Contact Voltage Rating In Volts

    28.0 dc at altitude

  • Contact Voltage Rating In Volts

    28.0 dc at sea level

  • Switch Actuator Indexing Position Quantity

    18 single actuator

  • Shaft Type

    round, flatted single actuator

  • Contact Load Current Rating

    350.0 milliamperes resistive load dc at altitude

  • Contact Load Current Rating

    50.0 milliamperes resistive load lowest ac voltage rating at sea level

  • Style Designator

    4a circular wafer, bushing mount

  • Thread Series Designator

    unef single mounting facility

  • Flat Height

    0.216 inches nominal single actuator

  • Shaft Diameter

    0.249 inches minimum single actuator and 0.252 inches maximum

  • Shaft Length

    0.406 inches minimum single actuator and 0.468 inches maximum

  • Nonturn Device Radius

    0.500 inches minimum at 3:00 o'clock and 0.531 inches maximum

  • Nonturn Device Type

    tab at 3:00 o'clock

  • Switch Contact Basic Design

    nonpile-up symmetrical

  • Pole Quantity

    1 single section rear

  • Throw Quantity

    15 single section rear

  • Mounting Method

    threaded bushing single mounting facility

  • Contact Voltage Rating In Volts

    115.0 lowest ac voltage rating at sea level

  • Contact Voltage Rating In Volts

    300.0 highest ac voltage rating at sea level

  • Shaft Flat/Slot Angular Location

    140.0 degrees from nonturn device single actuator

  • Terminal Type

    tab, solder lug

  • Contact Switching Action

    breaks before makes single section rear

  • Switch Actuator Positioning Increment

    20.0 degrees single actuator

  • Switch Actuator Stop Device Type

    fixed-adjustable stops single actuator

  • Contact Load Current Rating

    100.0 milliamperes resistive load ac at altitude

  • Contact Load Current Rating

    250.0 milliamperes resistive load highest ac voltage rating at sea level

  • Contact Load Current Rating

    500.0 milliamperes resistive load dc at sea level and 50.0 milliamperes inductive load

  • Thread Length

    0.312 inches nominal single mounting facility

  • Overall Length

    2.062 inches maximum

  • Overall Diameter

    2.328 inches maximum

  • Individual Section Quantity

    1

  • Thread Quantity Per Inch

    32 single mounting facility

  • Nominal Thread Size

    0.375 inches single mounting facility

  • Contact Voltage Rating In Volts

    115.0 lowest ac voltage rating at altitude

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...