NSN: 5930-00-508-0030

Switches

SWITCH,PRESSURE

5930 - Switches

SWITCH,PRESSURE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Contact Stimulus Rating

    0.40 actuation point minimum pounds per square inch gage and 0.10 differential point minimum pounds per square inch gage and 17.80 actuation point maximum pounds per square inch gage and 0.20 differential point maximum pounds per square inch gage

  • Mounting Facility Pattern

    two position in-line

  • Nominal Thread Size

    0.500 inches single pressure connection

  • Pressure Connector Type

    plain, threaded internal single connection

  • Overall Length

    3.968 inches nominal

  • Contact Action Stimulus

    increase

  • Err Default

    err default

  • Thread Series Designator

    npt single pressure connection

  • Overall Width

    3.500 inches nominal

  • Contact Adjustment Range

    +0.60/+18.00 actuation point pounds per square inch gage and +0.60/+18.00 deactuation point pounds per square inch gage

  • Contact Adjustment Type

    external deactuation point screw and external actuation point screw

  • Overall Height

    3.500 inches nominal

  • Proof Pressure

    60.00 pounds per square inch gage

  • Contact Load Current Rating

    500.0 milliamperes inductive load second voltage

  • Thread Quantity Per Inch

    14 single pressure connection

  • Unthreaded Mounting Hole Diameter

    0.203 inches nominal

  • Contact Adjustability

    deactuation point adjustable, preset and actuation point adjustable, preset

  • Style Designator

    rectangular

  • Thread Class

    3a single pressure connection

  • Media For Which Designed

    gas or liquid

  • Contact Voltage Rating In Volts

    125.0 ac at sea level first voltage

  • Frequency In Hertz

    60.0 first voltage

  • Nonpile-Up Contact Arrangement

    1 pole, double throw, one position momentary

  • Contact Load Current Rating

    10.0 amperes resistive load first voltage

  • Operating Temp Rating

    -55.0 deg celsius minimum and 100.0 deg fahrenheit maximum

  • Mounting Method

    unthreaded hole

  • Pressure Switch Type

    gage

  • Distance Between Mounting Facility Centers

    2.250 inches nominal

  • Contact Voltage Rating In Volts

    28.0 dc at sea level second voltage

  • Terminal Type

    wire lead

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...