NSN: 5930-00-714-5553

Switches

SWITCH,ROTARY

5930 - Switches

SWITCH,ROTARY

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Class

    2a single mounting facility

  • Thread Length

    0.375 inches nominal single mounting facility

  • Overall Length

    2.000 inches nominal

  • Overall Width

    1.360 inches minimum and 1.390 inches maximum

  • Overall Height

    1.516 inches minimum and 1.546 inches maximum

  • First Flat Length

    0.250 inches nominal single actuator

  • Shaft Length

    0.750 inches nominal single actuator

  • Individual Section Quantity

    2

  • Operating Temp Range

    -25.0 to 85.0 deg celsius

  • Throw Quantity

    2 each section rear

  • Contact Voltage Rating In Volts

    110.0 ac at sea level

  • Contact Voltage Rating In Volts

    28.0 dc at sea level

  • Switch Actuator Indexing Position Quantity

    3 single actuator

  • Contact Switching Action

    makes before breaks each section rear

  • Contact Load Current Rating

    1.0 amperes resistive load dc at sea level

  • Style Designator

    4 circular wafer, bushing mount

  • Thread Series Designator

    unef single mounting facility

  • Flat Height

    0.218 inches nominal single actuator

  • Shaft Diameter

    0.248 inches minimum single actuator and 0.250 inches maximum

  • Nonturn Device Radius

    0.531 inches nominal at 10:30 o'clock

  • Nonturn Device Type

    tab at 10:30 o'clock

  • Switch Contact Basic Design

    nonpile-up symmetrical

  • Pole Quantity

    2 each section rear

  • Mounting Method

    threaded bushing single mounting facility

  • Nominal Thread Size

    0.375 inches single mounting facility

  • Shaft Flat/Slot Angular Location

    90.0 degrees from nonturn device single actuator

  • Shaft Type

    round, flatted single actuator

  • Terminal Type

    tab, solder lug

  • Switch Actuator Positioning Increment

    60.0 degrees single actuator

  • Switch Actuator Stop Device Type

    fixed stop single actuator

  • Contact Load Current Rating

    0.5 amperes resistive load ac at sea level

  • Test Data Document

    90348-2174480 drawing

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...