Technical Characteristics

  • Pole Quantity

    2 single section front

  • Thread Class

    2a single mounting facility

  • Detent Rotational Torque Range

    +1.500/+5.000 inch-pounds single actuator

  • Operating Temp Range

    -65.0/+85.0 deg celsius

  • Nonturn Device Type

    tab at 5:00 o'clock

  • Terminal Type

    tab, solder lug

  • Shaft Flat/Slot Angular Location

    90.0 degrees from nonturn device single actuator

  • Pole Quantity

    2 single section rear

  • Contact Load Current Rating

    28.0 milliamperes resistive load dc at altitude

  • Contact Load Current Rating

    50.0 milliamperes resistive load ac at sea level

  • Switch Contact Basic Design

    nonpile-up symmetrical

  • Thread Series Designator

    unef single mounting facility

  • Contact Load Current Rating

    28.0 milliamperes resistive load dc at sea level

  • Shaft Length

    0.660 inches minimum single actuator and 0.720 inches maximum single actuator

  • Individual Section Quantity

    1

  • Contact Voltage Rating In Volts

    28.0 dc at altitude

  • Width Between Flats

    0.175 inches minimum single actuator and 0.195 inches maximum single actuator

  • Contact Voltage Rating In Volts

    28.0 dc at sea level

  • Throw Quantity

    3 single section front

  • Switch Actuator Positioning Increment

    30.0 degrees single actuator

  • Shaft Type

    round, parallel flatted single actuator

  • Overall Diameter

    1.324 inches minimum and 1.344 inches maximum

  • Throw Quantity

    3 single section rear

  • Switch Actuator Indexing Position Quantity

    3 single actuator

  • Switch Actuator Stop Device Type

    fixed stop single actuator

  • Shaft Diameter

    0.247 inches minimum single actuator and 0.251 inches maximum single actuator

  • Contact Voltage Rating In Volts

    115.0 ac at altitude

  • Style Designator

    circular wafer, bushing mount

  • Overall Length

    1.515 inches minimum and 1.595 inches maximum

  • Contact Voltage Rating In Volts

    115.0 ac at sea level

  • Contact Switching Action

    breaks before makes single section front

  • Err Default

    err default and err default

  • First Flat Length

    0.220 inches minimum single actuator and 0.280 inches maximum single actuator

  • Nominal Thread Size

    0.375 inches single mounting facility

  • Contact Load Current Rating

    100.0 milliamperes resistive load ac at altitude

  • Hazardous Locations/Environmental Protection

    vibration proof

  • Contact Switching Action

    breaks before makes single section rear

  • Mounting Method

    threaded bushing single mounting facility

  • Nonturn Device Radius

    0.350 inches minimum at 5:00 o'clock and 0.410 inches maximum at 5:00 o'clock

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...