NSN: 5930-00-771-0252

Switches

SWITCH,PRESSURE

5930 - Switches

SWITCH,PRESSURE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Method

    bracket and unthreaded hole

  • Nonpile-Up Contact Arrangement

    2 pole, double throw, one position momentary

  • Terminal Type

    connector, receptacle

  • Sensing Element Burst Pressure

    90.00 pounds per square inch gage

  • Unthreaded Mounting Hole Diameter

    0.219 inches minimum and 0.233 inches maximum

  • Media For Which Designed

    gas

  • Proof Pressure

    67.00 pounds per square inch gage

  • Operating Temp Rating

    -65.0 deg fahrenheit minimum and 300.0 deg fahrenheit maximum

  • Longest Horizontal Distance Between Mounting Centers

    3.625 inches nominal

  • Overall Width

    2.250 inches nominal

  • Longest Vertical Distance Between Mounting Centers

    1.500 inches nominal

  • Special Features

    independent switch actuations

  • Pressure Switch Type

    gage

  • Body Height

    2.470 inches nominal

  • Mounting Facility Pattern

    four position rectangular

  • Contact Action Stimulus

    increase