NSN: 5930-00-796-3749
Switches
SWITCH,PRESSURE
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Contact Load Current Rating
5.0 amperes resistive load second voltage and 5.0 amperes inductive load second voltage
-
Thread Quantity Per Inch
18 single pressure connection
-
Operating Temp Rating
-30.0 deg fahrenheit minimum and 160.0 deg fahrenheit maximum
-
Nonpile-Up Contact Arrangement
1 pole, double throw, one position momentary
-
Contact Voltage Rating In Volts
125.0 ac at sea level second voltage
-
Hazardous Locations/Environmental Protection
dustproof
-
Features Provided
electrical access port
-
Mounting Facility Pattern
three position circular
-
Unthreaded Mounting Hole Diameter
0.210 inches nominal
-
Frequency In Hertz
50.0 first voltage and 60.0 first voltage
-
Pressure Switch Type
gage
-
Contact Load Current Rating
5.0 amperes resistive load third voltage and 3.0 amperes inductive load third voltage
-
Contact Stimulus Rating
46.00 actuation point minimum pounds per square inch and 95.00 actuation point maximum pounds per square inch and 5.00 differential point minimum pounds per square inch and 8.50 differential point maximum pounds per square inch
-
Terminal Type
wire lead
-
Nominal Thread Size
0.250 inches single pressure connection
-
Mounting Facility Circle Radius
1.500 inches nominal
-
Contact Adjustability
deactuation point not adjustable and actuation point not adjustable
-
Overall Diameter
1.870 inches nominal
-
Pressure Connector Type
plain, threaded internal single connection
-
Contact Voltage Rating In Volts
28.0 dc at sea level third voltage
-
Contact Action Stimulus
increase
-
Mounting Method
base and unthreaded hole
-
Contact Load Current Rating
5.0 amperes resistive load first voltage and 5.0 amperes inductive load first voltage
-
Overall Length
3.900 inches maximum
-
Style Designator
cylindrical
-
Thread Series Designator
npt single pressure connection
-
Sensing Element Burst Pressure
500.00 pounds per square inch
-
Contact Voltage Rating In Volts
250.0 ac at sea level first voltage
-
Media For Which Designed
gas
-
Frequency In Hertz
50.0 second voltage and 60.0 second voltage
-
Body Diameter
1.440 nominal inches
-
Proof Pressure
1000.00 pounds per square inch