NSN: 5930-00-986-7280
Switches
SWITCH,THERMOSTATIC
SWITCH,THERMOSTATIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Temp Sensing Element Type
capillary tube-bulb
-
Nonpile-Up Contact Arrangement
1 pole, single throw, both positions maintained
-
Terminal Type
tab w/screw
-
Contact Load Current Rating
2.0 amperes resistive load third voltage
-
Contact Load Current Rating
3.4 amperes resistive load first voltage
-
Contact Load Current Rating
9.6 amperes resistive load fourth voltage
-
Contact Adjustability
deactuation point not adjustable and
-
Contact Adjustment Type
external actuation point screw
-
Contact Voltage Rating In Volts
115.0 dc at sea level fourth voltage
-
Overall Length
5.000 inches nominal
-
Overall Height
5.812 inches nominal
-
Body Length
4.782 inches nominal
-
Longest Horizontal Distance Between Mounting Centers
2.406 inches nominal
-
Longest Vertical Distance Between Mounting Centers
3.281 inches nominal
-
Overall Width
2.688 inches nominal
-
Capillary Tube Length
120.000 inches nominal
-
Bulb Length
3.625 inches nominal
-
Bulb Diameter
0.688 inches nominal
-
Shortest Horizontal Distance Between Mounting Centers
0.656 inches nominal
-
Mounting Method
bracket
-
Contact Action Stimulus
increase
-
Contact Load Current Rating
16.0 amperes resistive load second voltage
-
Contact Adjustability
actuation point adjustable
-
Contact Adjustment Range
510.00 to 625.00 actuation point degrees fahrenheit
-
Contact Voltage Rating In Volts
550.0 ac at sea level first voltage
-
Contact Voltage Rating In Volts
550.0 dc at sea level third voltage
-
Frequency In Hertz
60.0 single voltage
-
Design Control Reference
222-10nl2221594
-
Manufacturers Code
19278