NSN: 5930-00-994-6037

Switches

SWITCH,ROTARY

5930 - Switches

SWITCH,ROTARY

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Style Designator

    circular wafer, bushing mount

  • Shaft Length

    1.300 inches minimum single actuator and 1.320 inches maximum single actuator

  • Individual Section Quantity

    3

  • Throw Quantity

    11 each section front

  • Pole Quantity

    1 3rd section front

  • Overall Diameter

    1.620 inches minimum and 1.640 inches maximum

  • Err Default

    err default and err default

  • Contact Load Current Rating

    1.0 amperes resistive load ac at sea level

  • Nominal Thread Size

    0.375 inches single mounting facility

  • Pole Quantity

    2 1st section front

  • Flat Height

    0.213 inches minimum single actuator and 0.223 inches maximum single actuator

  • Shaft Type

    round, flatted single actuator

  • Throw Quantity

    6 1st section rear

  • Contact Switching Action

    breaks before makes 4th section rear

  • Mounting Method

    threaded bushing single mounting facility

  • Pole Quantity

    2 1st section rear

  • Pole Quantity

    2 2nd section front

  • Switch Actuator Indexing Position Quantity

    12 single actuator

  • Nonturn Device Type

    tab at 3:00 o'clock

  • Overall Length

    2.695 inches minimum and 2.725 inches maximum

  • Pole Quantity

    2 2nd section rear

  • Terminal Type

    tab, solder lug

  • Contact Voltage Rating In Volts

    110.0 ac at sea level

  • Throw Quantity

    7 2nd section rear

  • Switch Contact Basic Design

    nonpile-up symmetrical

  • Thread Series Designator

    unef single mounting facility

  • Shaft Flat/Slot Angular Location

    210.0 degrees from nonturn device single actuator

  • Nonturn Device Radius

    0.521 inches minimum at 3:00 o'clock and 0.541 inches maximum at 3:00 o'clock

  • Shaft Diameter

    0.248 inches minimum single actuator and 0.250 inches maximum single actuator

  • Contact Voltage Rating In Volts

    28.0 dc at sea level

  • Test Data Document

    05869-721815-45 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Contact Switching Action

    breaks before makes 1st section rear

  • Switch Actuator Positioning Increment

    30.0 degrees single actuator

  • Contact Load Current Rating

    2.0 amperes resistive load dc at sea level

  • Operating Temp Range

    -25.0/+85.0 deg celsius

  • Contact Switching Action

    breaks before makes each section front

  • First Flat Length

    0.300 inches minimum single actuator and 0.320 inches maximum single actuator

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...