NSN: 5930-01-019-5249
Switches
SWITCH,ROTARY
SWITCH,ROTARY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Type
tab, solder lug
-
Operating Temp Range
-65.0/+125.0 deg celsius
-
Switch Contact Basic Design
nonpile-up symmetrical
-
Thread Series Designator
unef single mounting facility
-
Shaft Diameter
0.248 inches minimum single actuator and 0.251 inches maximum single actuator
-
Throw Quantity
3 each section rear
-
Contact Voltage Rating In Volts
28.0 dc at sea level
-
Nonturn Device Radius
0.360 inches minimum at 3:00 o'clock and 0.390 inches maximum at 3:00 o'clock
-
Overall Length
2.554 inches minimum and 2.677 inches maximum
-
Special Features
item must comply with rqmt of the desc production std no. l02074. for navy nuclear propulsion plant products only
-
Shaft Flat/Slot Angular Location
180.0 degrees from contact position 1 single actuator
-
Switch Actuator Positioning Increment
30.0 degrees single actuator
-
Flat Height
0.215 inches minimum single actuator and 0.221 inches maximum single actuator
-
Shaft Length
0.834 inches minimum single actuator and 0.914 inches maximum single actuator
-
Rotor Through Connection Quantity
4 each section
-
Switch Actuator Indexing Position Quantity
3 single actuator
-
Switch Actuator Stop Device Type
fixed stop single actuator
-
Detent Rotational Torque Range
+2.500/+7.000 inch-pounds single actuator
-
Contact Load Current Rating
75.0 milliamperes resistive load ac at sea level
-
Individual Section Quantity
3
-
Contact Voltage Rating In Volts
115.0 ac at sea level
-
Contact Switching Action
breaks before makes each section rear
-
Err Default
err default and err default
-
Criticality Code Justification
feat
-
Style Designator
tap, circular, bushing mount
-
Nominal Thread Size
0.375 inches single mounting facility
-
Contact Load Current Rating
250.0 milliamperes resistive load dc at sea level and 100.0 milliamperes inductive load dc at sea level
-
Shaft Type
round, flatted single actuator
-
Hazardous Locations/Environmental Protection
explosion proof
-
Mounting Method
threaded bushing single mounting facility
-
Overall Diameter
1.155 inches minimum and 1.185 inches maximum
-
First Flat Length
0.230 inches minimum single actuator and 0.270 inches maximum single actuator
-
Pole Quantity
4 each section front
-
Thread Class
2a single mounting facility
-
Nonturn Device Type
tab at 3:00 o'clock