NSN: 5930-01-019-5254

Switches

SWITCH,ROTARY

5930 - Switches

SWITCH,ROTARY

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Contact Load Current Rating

    75.0 milliamperes resistive load ac at sea level

  • Overall Length

    5.226 inches minimum and 5.349 inches maximum

  • Switch Actuator Indexing Position Quantity

    6 single actuator

  • Contact Voltage Rating In Volts

    115.0 ac at sea level

  • Contact Switching Action

    makes before breaks 3rd section rear

  • Err Default

    err default and err default

  • Criticality Code Justification

    feat

  • Style Designator

    tap, circular, bushing mount

  • Nominal Thread Size

    0.375 inches single mounting facility

  • Contact Load Current Rating

    250.0 milliamperes resistive load dc at sea level and 100.0 milliamperes inductive load dc at sea level

  • Pole Quantity

    2 each section front

  • Shaft Type

    round, flatted single actuator

  • Contact Switching Action

    makes before breaks 4th section rear

  • Rotor Through Connection Quantity

    2 each section

  • Hazardous Locations/Environmental Protection

    explosion proof

  • Mounting Method

    threaded bushing single mounting facility

  • Contact Switching Action

    breaks before makes 10th section rear

  • Overall Diameter

    1.155 inches minimum and 1.185 inches maximum

  • First Flat Length

    0.230 inches minimum single actuator and 0.270 inches maximum single actuator

  • Thread Class

    2a single mounting facility

  • Contact Switching Action

    makes before breaks 5th section rear

  • Nonturn Device Type

    tab at 3:00 o'clock

  • Terminal Type

    tab, solder lug

  • Operating Temp Range

    -65.0/+125.0 deg celsius

  • Contact Switching Action

    makes before breaks 6th section rear

  • Switch Contact Basic Design

    nonpile-up symmetrical

  • Thread Series Designator

    unef single mounting facility

  • Shaft Diameter

    0.248 inches minimum single actuator and 0.251 inches maximum single actuator

  • Contact Switching Action

    breaks before makes 7th section rear

  • Contact Voltage Rating In Volts

    28.0 dc at sea level

  • Individual Section Quantity

    10

  • Nonturn Device Radius

    0.360 inches minimum at 3:00 o'clock and 0.390 inches maximum at 3:00 o'clock

  • Shaft Flat/Slot Angular Location

    180.0 degrees from contact position 1 single actuator

  • Contact Switching Action

    breaks before makes 8th section rear

  • Special Features

    item must comply with rqmt of the desc production std no. l02080. for navy nuclear propulsion plant products only

  • Contact Switching Action

    makes before breaks 1st section rear

  • Switch Actuator Positioning Increment

    30.0 degrees single actuator

  • Flat Height

    0.215 inches minimum single actuator and 0.221 inches maximum single actuator

  • Shaft Length

    0.834 inches minimum single actuator and 0.914 inches maximum single actuator

  • Contact Switching Action

    breaks before makes 9th section rear

  • Switch Actuator Stop Device Type

    fixed stop single actuator

  • Throw Quantity

    6 each section rear

  • Contact Switching Action

    makes before breaks 2nd section rear

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...