NSN: 5930-01-045-5938
Switches
SWITCH,PRESSURE
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Distance Between Mounting Facility Centers
2.250 inches nominal
-
Features Provided
automatic reset
-
Terminal Type
wire lead
-
Nominal Thread Size
0.250 inches single pressure connection
-
Contact Load Current Rating
10.0 amperes inductive load second voltage
-
Mounting Facility Pattern
two position in-line
-
Pressure Connector Type
plain, threaded internal single connection
-
Overall Length
3.968 inches nominal
-
Contact Action Stimulus
increase
-
Contact Voltage Rating In Volts
480.0 ac at sea level second voltage
-
Mounting Method
bracket and unthreaded hole
-
Thread Series Designator
npt single pressure connection
-
Overall Width
3.500 inches nominal
-
Contact Adjustability
actuation point adjustable and deactuation point adjustable
-
Contact Load Current Rating
3.0 amperes inductive load first voltage
-
Inside Diameter
0.250 inches nominal single connection
-
Hazardous Locations/Environmental Protection
watertight
-
Contact Load Current Rating
0.5 amperes inductive load third voltage
-
Contact Adjustment Type
external actuation point screw and external deactuation point screw
-
Overall Height
3.500 inches nominal
-
Contact Adjustment Range
+3.90/+80.00 actuation point pounds per square inch gage
-
Unthreaded Mounting Hole Diameter
0.203 inches nominal
-
Media For Which Designed
gas or liquid
-
Contact Voltage Rating In Volts
125.0 ac at sea level first voltage
-
Frequency In Hertz
60.0 first voltage
-
Nonpile-Up Contact Arrangement
1 pole, double throw, one position momentary
-
Pressure Switch Type
absolute
-
Proof Pressure
160.00 pounds per square inch gage
-
Contact Voltage Rating In Volts
24.0 dc at sea level third voltage