NSN: 5930-01-053-7671
Switches
SWITCH,PRESSURE
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Contact Adjustability
actuation point not adjustable
-
Terminal Type
connector, receptacle
-
Overall Width
3.000 inches nominal
-
Proof Pressure
10.00 pounds per square inch gage
-
Operating Temp Rating
-65.0 deg fahrenheit minimum and 120.0 deg fahrenheit maximum
-
Media For Which Designed
gas
-
Contact Load Current Rating
1.0 milliamperes resistive load single voltage
-
Features Provided
hermetically sealed case
-
Longest Horizontal Distance Between Mounting Centers
2.500 inches nominal
-
Style Designator
cylindrical w/flange
-
Nonpile-Up Contact Arrangement
1 pole, double throw, one position momentary
-
Overall Length
3.500 inches maximum
-
Mounting Method
unthreaded hole
-
Unthreaded Mounting Hole Diameter
0.210 inches nominal
-
Overall Height
3.000 inches nominal
-
Pressure Switch Type
gage
-
Contact Voltage Rating In Volts
28.0 dc at sea level single voltage
-
Contact Stimulus Rating
44.04 actuation point nominal inches of water and 38.50 deactuation point nominal inches of water
-
Mounting Facility Pattern
four position rectangular
-
Longest Vertical Distance Between Mounting Centers
2.500 inches nominal
-
Contact Action Stimulus
increase