NSN: 5930-01-054-4704
Switches
SWITCH,PRESSURE
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Pattern
isosceles triangle
-
Overall Height
2.500 inches nominal
-
Longest Horizontal Distance Between Mounting Centers
1.780 inches nominal
-
Contact Load Current Rating
15.0 amperes resistive load first voltage and 15.0 amperes inductive load first voltage
-
Nominal Thread Size
0.125 inches single pressure connection
-
Shortest Horizontal Distance Between Mounting Centers
0.890 inches nominal
-
Contact Load Current Rating
6.0 amperes resistive load second voltage and 5.0 amperes inductive load second voltage
-
Overall Length
3.500 inches nominal
-
Thread Series Designator
npt all pressure connection
-
Thread Quantity Per Inch
27 all pressure connection
-
Thread Class
3b all threaded hole
-
Thread Series Designator
unc all threaded hole
-
Nominal Thread Size
0.250 inches all threaded hole
-
Thread Quantity Per Inch
20 all threaded hole
-
Operating Temp Rating
-34.0 deg celsius minimum and 71.0 deg celsius maximum
-
Longest Vertical Distance Between Mounting Centers
1.965 inches nominal
-
Err Default
err default
-
Nonpile-Up Contact Arrangement
1 pole, double throw, one position momentary
-
Proof Pressure
4500.00 pounds per square inch
-
Pressure Connector Type
plain, threaded internal all connections
-
Mounting Method
threaded hole
-
Pressure Switch Type
differential
-
Overall Width
4.300 inches nominal
-
Frequency In Hertz
50.0 first voltage and 60.0 first voltage
-
Contact Voltage Rating In Volts
28.0 dc at sea level second voltage
-
Contact Voltage Rating In Volts
480.0 ac at sea level first voltage
-
Terminal Type
wire lead