Technical Characteristics

  • Contact Action Stimulus

    increase

  • Distance Between Mounting Facility Centers

    4.250 inches nominal

  • Contact Load Current Rating

    400.0 milliamperes resistive load third voltage and 60.0 milliamperes inductive load third voltage

  • Overall Length

    8.000 inches maximum

  • Thread Quantity Per Inch

    14 single pressure connection

  • Contact Load Current Rating

    15.0 amperes resistive load second voltage and 15.0 amperes inductive load second voltage

  • Contact Adjustment Type

    internal actuation point serrated nut

  • Operating Temp Rating

    -34.0 deg celsius minimum and 71.0 deg celsius maximum

  • Nonpile-Up Contact Arrangement

    1 pole, double throw, one position momentary

  • Proof Pressure

    4500.00 pounds per square inch

  • Contact Voltage Rating In Volts

    125.0 ac at sea level second voltage

  • Mounting Method

    unthreaded hole

  • Overall Width

    4.750 inches nominal

  • Terminal Type

    wire lead

  • Mounting Facility Pattern

    two position in-line

  • Nominal Thread Size

    0.500 inches single pressure connection

  • Pressure Connector Type

    plain, threaded internal single connection

  • Contact Adjustability

    actuation point adjustable

  • Unthreaded Mounting Hole Diameter

    0.265 inches nominal

  • Contact Adjustment Range

    +4.00/+15.00 actuation point pounds per square inch

  • Thread Series Designator

    npt single pressure connection

  • Contact Stimulus Rating

    6.00 differential point nominal pounds per square inch

  • Contact Voltage Rating In Volts

    125.0 dc at sea level third voltage

  • Overall Height

    3.300 inches maximum

  • Contact Load Current Rating

    15.0 amperes resistive load first voltage and 15.0 amperes inductive load first voltage

  • Frequency In Hertz

    50.0 second voltage and 60.0 second voltage

  • Frequency In Hertz

    50.0 first voltage and 60.0 first voltage

  • Pressure Switch Type

    gage

  • Contact Voltage Rating In Volts

    480.0 ac at sea level first voltage

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...