NSN: 5930-01-146-4807

Switches

SWITCH,PRESSURE

5930 - Switches

SWITCH,PRESSURE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Contact Voltage Rating In Volts

    125.0 dc at sea level third voltage

  • Hazardous Locations/Environmental Protection

    explosion proof

  • Contact Stimulus Rating

    0.40 differential point minimum pounds per square inch and 1.20 actuation point minimum pounds per square inch and 18.00 actuation point maximum pounds per square inch and 17.20 differential point maximum pounds per square inch

  • Contact Load Current Rating

    15.0 amperes resistive load first voltage and 15.0 amperes inductive load first voltage

  • Frequency In Hertz

    50.0 second voltage and 60.0 second voltage

  • Features Provided

    hermetically sealed case

  • Nonpile-Up Contact Arrangement

    1 pole, double throw, both positions maintained

  • Contact Load Current Rating

    15.0 amperes resistive load second voltage and 15.0 amperes inductive load second voltage

  • Thread Series Designator

    npt all pressure connection

  • Contact Adjustment Type

    internal actuation point screw with scale and internal deactuation point screw with scale

  • Thread Quantity Per Inch

    18 all pressure connection

  • Contact Voltage Rating In Volts

    125.0 ac at sea level first voltage

  • Operating Temp Rating

    -34.0 deg celsius minimum and 71.0 deg celsius maximum

  • Pressure Connector Type

    plain, threaded internal all connections

  • Mounting Method

    unthreaded hole

  • Pressure Switch Type

    differential

  • Frequency In Hertz

    50.0 first voltage and 60.0 first voltage

  • Terminal Type

    wire lead

  • Nominal Thread Size

    0.250 inches single pressure connection

  • Contact Action Stimulus

    increase

  • Contact Voltage Rating In Volts

    480.0 ac at sea level second voltage

  • Unthreaded Mounting Hole Diameter

    0.265 inches nominal

  • Contact Adjustability

    deactuation point adjustable and actuation point adjustable

  • Contact Adjustment Range

    +1.20/+18.00 actuation point pounds per square inch and +0.40/+17.20 deactuation point pounds per square inch

  • Media For Which Designed

    liquid

  • Contact Load Current Rating

    0.4 amperes resistive load third voltage and 0.2 amperes inductive load third voltage

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...