NSN: 5930-01-163-3200
Switches
SWITCH,THERMOSTATIC
SWITCH,THERMOSTATIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Operating Temp Rating
-65.0 deg fahrenheit minimum and 400.0 deg fahrenheit maximum
-
Contact Stimulus Rating
140.00 actuation point nominal degrees fahrenheit and 120.00 deactuation point nominal degrees fahrenheit
-
Mounting Method
bracket and unthreaded hole and slot
-
Contact Load Current Rating
1.0 amperes inductive load second voltage and 2.0 amperes resistive load second voltage and 500.0 milliamperes lamp load second voltage
-
Body Diameter
0.560 inches minimum and 0.640 inches maximum
-
Body Height
0.350 inches minimum and 0.405 inches maximum
-
Overall Height
0.711 inches nominal
-
Specification/Standard Data
81349-mil-s-24236/24 government specification
-
Style Designator
disc w/flange
-
Features Provided
hermetically sealed case
-
Distance Between Mounting Facility Centers
0.937 inches nominal
-
Terminal Type
tab, solder lug
-
Overall Length
1.200 inches minimum and 1.260 inches maximum
-
Unthreaded Mounting Hole Diameter
0.140 inches nominal
-
Temp Sensing Element Type
internal sensor
-
Mounting Slot Width
0.140 inches nominal
-
Media For Which Designed
gas or liquid
-
~1
data on certain environmental and performanc
-
Test Data Document
81349-mil-s-24236 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Contact Action Stimulus
increase
-
Mounting Facility Pattern
two position in-line
-
Contact Adjustability
deactuation point not adjustable and actuation point not adjustable
-
Contact Voltage Rating In Volts
28.0 dc at sea level second voltage
-
Contact Load Current Rating
2.0 amperes resistive load first voltage and 1.0 amperes inductive load first voltage and 500.0 milliamperes lamp load first voltage
-
Nonpile-Up Contact Arrangement
1 pole, double throw, one position momentary
-
Frequency In Hertz
60.0 first voltage
-
Contact Voltage Rating In Volts
115.0 ac at sea level first voltage